Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Iperception ; 12(3): 20416695211020019, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34164106

RESUMO

We report a novel visual illusion we call the Ring Rotation Illusion (RRI). When a ring of stationary points replaces a circular outline, the ring of points appears to rotate to a halt, although no actual motion has been displayed. Three experiments evaluate the clarity of the illusory rotation. Clarity decreased as the diameter of the circle and ring increased and increased as the number of points forming the ring increased. The optimal interstimulus interval (ISI) between the circle and ring was 90 ms when stimulus presentations lasted 100 ms but 0 ms with 500 ms presentations. We compare the RRI to the Motion Bridging Effect (MBE), a similar illusion in which a stationary ring of points replaces an initial ring of points that spins so rapidly it looks like a stationary outline. A rotation of the stationary ring is seen that usually matches the direction of the initial ring's invisible spin. Participants reported a slightly more frequent and clearer motion percept with the MBE than RRI. ISI manipulations had similar effects on the two illusions, but the effects of number of points and ring diameter were largely restricted to the RRI. We suggest that both the RRI and MBE motion percepts are produced by a visual heuristic that holds that the transition from an outline circle to a ring of points is plausibly explained by a rapid spin decelerating to a halt, but in the case of the MBE, an additional direction-sensitive mechanism contributes to this percept.

2.
Iperception ; 11(3): 2041669520925111, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32547723

RESUMO

A ring of points that is rotated so rapidly is perceived as a stationary outline circle that can induce an illusory rotation with the same spin direction in a subsequently presented ring of stationary points. This motion bridging effect (MBE) demonstrates that motion information can be conveyed by temporal frequencies generally thought to exceed the processing capabilities of the human visual system. It was first described in displays shown with an analog oscilloscope, but the rapid rotation rates needed to produce the MBE have heretofore prevented it from being investigated with conventional raster scan monitors. Here, we demonstrate the MBE can be reliably generated using the new generation of 240 Hz LCD gaming monitors, and exhibits basic characteristics similar to those reported previously. These monitors therefore provide a readily available resource for research on the MBE and the studies of the visual processing rapid motions in general.

3.
Front Neurol ; 11: 13, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32082241

RESUMO

Background: Computed tomography angiography (CTA) is frequently used with computed tomography perfusion imaging (CTP) to evaluate whether endovascular vasospasm treatment is indicated for subarachnoid hemorrhage patients with delayed cerebral ischemia. However, objective parameters for CTA evaluation are lacking. In this study, we used an automated, investigator-independent, digital method to detect vasospasm, and we evaluated whether the method could predict the need for subsequent endovascular vasospasm treatment. Methods: We retrospectively reviewed the charts and analyzed imaging data for 40 consecutive patients with subarachnoid hemorrhages. The cerebrovascular trees were digitally reconstructed from CTA data, and vessel volume and the length of the arteries of the circle of Willis and their peripheral branches were determined. Receiver operating characteristic curve analysis based on a comparison with digital subtraction angiographies was used to determine volumetric thresholds that indicated severe vasospasm for each vessel segment. Results: The automated threshold-based volumetric evaluation of CTA data was able to detect severe vasospasm with high sensitivity and negative predictive value for predicting cerebral hypoperfusion on CTP, although the specificity and positive predictive value were low. Combining the automated detection of vasospasm on CTA and cerebral hypoperfusion on CTP was superior to CTP or CTA alone in predicting endovascular vasospasm treatment within 24 h after the examination. Conclusions: This digital volumetric analysis of the cerebrovascular tree allowed the objective, investigator-independent detection and quantification of vasospasms. This method could be used to standardize diagnostics and the selection of subarachnoid hemorrhage patients with delayed cerebral ischemia for endovascular diagnostics and possible interventions.

4.
World Neurosurg ; 134: 284-291, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31678314

RESUMO

BACKGROUND: A considerable number of patients with subarachnoid hemorrhage (SAH) develop vasospasms of the infratentorial arteries. Transcranial Doppler sonography (TCD) is used to screen for vasospasm. In this study, we used a technical modification that combines TCD with an image guidance device that the operator can use to navigate to the ultrasonic window and to predefined intracranial vascular targets. Our aim was to analyze the feasibility, spatial precision, and spatial reproducibility of serial image-guided TCD of infratentorial and-for comparison-supratentorial arteries in the clinical setting of monitoring for vasospasm after SAH. METHODS: The study included 10 SAH patients, who each received 5 serial image-guided TCD examinations. Using computed tomography angiography data, trajectories to the infratentorial and supratentorial cerebral arteries were planned and loaded into an image guidance device tracking the Doppler probe. As a measure of spatial precision and spatial reproducibility, we analyzed the distances between the positions of preplanned vascular targets and optimal Doppler signals. RESULTS: The mean distance between preplanned and optimal target points was 4.8 ± 2.1 mm (first exam), indicating high spatial precision. The spatial precision decreased with increasing depth of the vascular target. In all patients, image-guided TCD detected all predefined supratentorial and infratentorial vascular segments. There were no significant changes in spatial precision in serial exams, indicating high reproducibility. CONCLUSIONS: Image-guided TCD is feasible for supratentorial and infratentorial arteries. It shows high spatial precision and reproducibility. This study provides a basis for future clinical studies on image-guided TCD for post-SAH vasospasm screening.


Assuntos
Artéria Basilar/diagnóstico por imagem , Artérias Cerebrais/diagnóstico por imagem , Hemorragia Subaracnóidea/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Vasoespasmo Intracraniano/diagnóstico por imagem , Artéria Vertebral/diagnóstico por imagem , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Isquemia Encefálica/etiologia , Angiografia Cerebral , Angiografia por Tomografia Computadorizada , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Hemorragia Subaracnóidea/complicações , Vasoespasmo Intracraniano/etiologia
5.
J Vis ; 19(5): 13, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31100129

RESUMO

The Motion Bridging Effect (MBE) is an illusion in which a motion that is not consciously visible generates a visible motion aftereffect that is predominantly in the same direction as the adapter motion. In the initial study of the MBE (Mattler & Fendrich, 2010), a ring of 16 points was rotated at angular velocities as high as 2250°/s so that observers saw only an unbroken outline circle and performed at chance when asked to report the ring's rotation direction. However, when the rotating ring was replaced by a veridically stationary ring of 16 points, the stationary ring appeared to visibly spin to a halt, principally in the same direction as the initial ring's rotation. Here we continue to investigate the stimulus dependencies of the MBE. We find the MBE, measured by the correspondence between the direction of the invisible rotation of the spinning ring and perceived rotation of the stationary ring, increases as the number of points used to construct the rings decreases and grows stronger as the diameter of the rings get larger. We consider the potential contributions of temporal frequency, retinal eccentricity, luminance levels, and the separation between the points forming the rings as mediators of these effects. Data is discussed with regard to the detection of real movement and apparent motion. We conclude that the detection of the rapid rotation of the spinning ring is likely to be modulated by temporal frequency of luminance changes along the ring perimeter while the point-distance may modulate an apparent motion produced by the transition from the perceptually unbroken spinning ring to the point-defined stationary ring.


Assuntos
Estado de Consciência/fisiologia , Ilusões/fisiologia , Percepção de Movimento/fisiologia , Adulto , Feminino , Humanos , Masculino , Estimulação Luminosa , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...